Carbon oxides, Hydrogen fluoride, silicon oxides
Wear self-contained breathing apparatus for firefighting if necessary.
Use water spray to cool unopened containers.
HEALTH | 3 | Short exposure could cause serious temporary or moderate residual injury (e.g. liquid hydrogen, sulfuric acid, calcium hypochlorite, hexafluorosilicic acid) | |
FIRE | 3 | Liquids and solids (including finely divided suspended solids) that can be ignited under almost all ambient temperature conditions . Liquids having a flash point below 22.8 °C (73 °F) and having a boiling point at or above 37.8 °C (100 °F) or having a flash point between 22.8 and 37.8 °C (73 and 100 °F). (e.g. gasoline, acetone) | |
REACT | 0 | Normally stable, even under fire exposure conditions, and is not reactive with water (e.g. helium,N2) | |
SPEC. HAZ. |
Use personal protective equipment. Avoid breathing vapors, mist or gas. Ensure adequate ventilation. Remove all sources of ignition. Evacuate personnel to safe areas. Beware of vapors accumulating to form explosive concentrations. Vapors can accumulate in low areas.
For personal protection see section 8.
Prevent further leakage or spillage if safe to do so. Do not let product enter drains.
Contain spillage, and then collect with an electrically protected vacuum cleaner or by wet- brushing and place in container for disposal according to local regulations (see section 13).
For disposal see section 13.
Avoid inhalation of vapor or mist.
Keep away from sources of ignition - No smoking.Take measures to prevent the build up of electrostatic charge.
For precautions see section 2.2.
Store in cool place. Keep container tightly closed in a dry and well-ventilated place. Containers which are opened must be carefully resealed and kept upright to prevent leakage.
Store under inert gas. Moisture sensitive.
Apart from the uses mentioned in section 1.2 no other specific uses are stipulated
Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and at the end of workday.
Tightly fitting safety goggles. Faceshield (8-inch minimum). Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).
Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands.
The selected protective gloves have to satisfy the specifications of Regulation (EU) 2016/425 and the standard EN 374 derived from it.
Complete suit protecting against chemicals, Flame retardant antistatic protective clothing., The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace.
Where risk assessment shows air-purifying respirators are appropriate use a full- face respirator with multi-purpose combination (US) or type ABEK (EN 14387) respirator cartridges as a backup to engineering controls. If the respirator is the sole means of protection, use a full-face supplied air respirator. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).
Prevent further leakage or spillage if safe to do so. Do not let product enter drains.
Relative vapor density
6,43 - (Air = 1.0)
No data available
Stable under recommended storage conditions.
No data available
Heat, flames and sparks. Extremes of temperature and direct sunlight.
Oxidizing agents, acids, Bases, Reducing agents
Hazardous decomposition products formed under fire conditions. - Carbon oxides, Hydrogen fluoride, silicon oxides
Other decomposition products - No data available
In the event of fire: see section 5
No data available
No data available
No data available
No data available
PBT/vPvB assessment not available as chemical safety assessment not required/not conducted
No data available
Burn in a chemical incinerator equipped with an afterburner and scrubber but exert extra care in igniting as this material is highly flammable. Offer surplus and non-recyclable solutions to a licensed disposal company.
Dispose of as unused product.
ADR/RID: 2924 IMDG: 2924 IATA: 2924
ADR/RID: FLAMMABLE LIQUID, CORROSIVE, N.O.S. (Trimethylsilyl trifluoroacetate) IMDG: FLAMMABLE LIQUID, CORROSIVE, N.O.S. (Trimethylsilyl trifluoroacetate) IATA: Flammable liquid, corrosive, n.o.s. (Trimethylsilyl trifluoroacetate)
ADR/RID: 3 (8) IMDG: 3 (8) IATA: 3 (8)
ADR/RID: II IMDG: II IATA: II
ADR/RID: no IMDG Marine pollutant: no IATA: no
No data available
【1】CAMEO Chemicals, website: http://cameochemicals.noaa.gov/search/simple
【2】ChemIDplus, website: http://chem.sis.nlm.nih.gov/chemidplus/chemidlite.jsp
【3】ECHA - European Chemicals Agency, website: https://echa.europa.eu/
【4】eChemPortal - The Global Portal to Information on Chemical Substances by OECD, website: http://www.echemportal.org/echemportal/index?pageID=0&request_locale=en
【5】ERG - Emergency Response Guidebook by U.S. Department of Transportation, website: http://www.phmsa.dot.gov/hazmat/library/erg
【6】Germany GESTIS-database on hazard substance, website: http://www.dguv.de/ifa/gestis/gestis-stoffdatenbank/index-2.jsp
【7】HSDB - Hazardous Substances Data Bank, website: https://toxnet.nlm.nih.gov/newtoxnet/hsdb.htm
【8】IARC - International Agency for Research on Cancer, website: http://www.iarc.fr/
【9】IPCS - The International Chemical Safety Cards (ICSC), website: http://www.ilo.org/dyn/icsc/showcard.home
【10】Sigma-Aldrich, website: https://www.sigmaaldrich.com/
The information in this MSDS is only applicable to the specified product, unless otherwise specified, it is not applicable to the mixture of this product and other substances. This MSDS only provides information on the safety of the product for those who have received the appropriate professional training for the user of the product. Users of this MSDS must make independent judgments on the applicability of this SDS. The authors of this MSDS will not be held responsible for any harm caused by the use of this MSDS.