Carbon oxides Sulfur oxides Combustible.
No data available
No data available
HEALTH | 1 | Exposure would cause irritation with only minor residual injury (e.g. acetone, sodium bromate, potassium chloride) | |
FIRE | 1 | Materials that require considerable preheating, under all ambient temperature conditions, before ignition and combustion can occur. Includes some finely divided suspended solids that do not require heating before ignition can occur. Flash point at or above 93.3 °C (200 °F). (e.g. mineral oil, ammonia) | |
REACT | 0 | Normally stable, even under fire exposure conditions, and is not reactive with water (e.g. helium,N2) | |
SPEC. HAZ. |
For personal protection see section 8.
No data available
No data available
For disposal see section 13.
For precautions see section 2.2.
No data available
Apart from the uses mentioned in section 1.2 no other specific uses are stipulated
Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands.
The selected protective gloves have to satisfy the specifications of Regulation (EU) 2016/425 and the standard EN 374 derived from it.
Full contact
Material: Chloroprene
Minimum layer thickness: 0,6 mm Break through time: 480 min
Material tested:Camapren? (KCL 722 / Aldrich Z677493, Size M)
Splash contact Material: Nitrile rubber
Minimum layer thickness: 0,2 mm Break through time: 30 min
Material tested:Dermatril? P (KCL 743 / Aldrich Z677388, Size M)
data source: KCL GmbH, D-36124 Eichenzell, phone +49 (0)6659 87300, e-mail sales@kcl.de, test method: EN374
If used in solution, or mixed with other substances, and under conditions which differ from EN 374, contact the supplier of the EC approved gloves. This recommendation is advisory only and must be evaluated by an industrial hygienist and safety officer familiar with the specific situation of anticipated use by our customers. It should not be construed as offering an approval for any specific use scenario.
Prevent product from entering drains.
No data available
No data available
No data available
Risk of explosion with:
acetylidene organic halides perchlorates Acid chlorides
nonmetallic halides iron(III) compounds nitrates
fluorides chlorates hydrides perchloric acid
Oxides of phosphorus Nitric acid
silver compounds silicon compounds silanes
acid halides
Exothermic reaction with:
boron compounds oxyhalogenic compounds Potassium
sodium
Strong oxidizing agents phosphorus halides strong reducing agents Acid chlorides
Strong acids silver salt nitrogen dioxide
Risk of ignition or formation of inflammable gases or vapours with: potassium permanganate
No data available
various plastics, Metals
In the event of fire: see section 5
static test EC50 - Daphnia magna (Water flea) - 24,6 mg/l - 48 h (OECD Test Guideline 202)
17.000 mg/l - 72 h (OECD Test Guideline 201)
Remarks: (IUCLID)
EC50 - activated sludge - 10 - 100 mg/l - 30 min Remarks: (IUCLID)
Biodegradability aerobic - Exposure time 28 d
Result: 31 % - Not readily biodegradable. (OECD Test Guideline 301D)
This substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher.
ADR/RID: - IMDG: - IATA: -
ADR/RID: - IMDG: - IATA: -
ADR/RID: - IMDG: - IATA: -
ADR/RID: no IMDG Marine pollutant: no IATA: no
No data available
【1】CAMEO Chemicals, website: http://cameochemicals.noaa.gov/search/simple
【2】ChemIDplus, website: http://chem.sis.nlm.nih.gov/chemidplus/chemidlite.jsp
【3】ECHA - European Chemicals Agency, website: https://echa.europa.eu/
【4】eChemPortal - The Global Portal to Information on Chemical Substances by OECD, website: http://www.echemportal.org/echemportal/index?pageID=0&request_locale=en
【5】ERG - Emergency Response Guidebook by U.S. Department of Transportation, website: http://www.phmsa.dot.gov/hazmat/library/erg
【6】Germany GESTIS-database on hazard substance, website: http://www.dguv.de/ifa/gestis/gestis-stoffdatenbank/index-2.jsp
【7】HSDB - Hazardous Substances Data Bank, website: https://toxnet.nlm.nih.gov/newtoxnet/hsdb.htm
【8】IARC - International Agency for Research on Cancer, website: http://www.iarc.fr/
【9】IPCS - The International Chemical Safety Cards (ICSC), website: http://www.ilo.org/dyn/icsc/showcard.home
【10】Sigma-Aldrich, website: https://www.sigmaaldrich.com/
The information in this MSDS is only applicable to the specified product, unless otherwise specified, it is not applicable to the mixture of this product and other substances. This MSDS only provides information on the safety of the product for those who have received the appropriate professional training for the user of the product. Users of this MSDS must make independent judgments on the applicability of this SDS. The authors of this MSDS will not be held responsible for any harm caused by the use of this MSDS.