Carbon oxides Nitrogen oxides (NOx) Combustible.
Vapors are heavier than air and may spread along floors. Forms explosive mixtures with air on intense heating.
Development of hazardous combustion gases or vapours possible in the event of fire.
Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing.
Suppress (knock down) gases/vapors/mists with a water spray jet. Prevent fire extinguishing water from contaminating surface water or the ground water system.
HEALTH | 2 | Intense or continued but not chronic exposure could cause temporary incapacitation or possible residual injury (e.g. diethyl ether, ammonium phosphate, iodine) | |
FIRE | 1 | Materials that require considerable preheating, under all ambient temperature conditions, before ignition and combustion can occur. Includes some finely divided suspended solids that do not require heating before ignition can occur. Flash point at or above 93.3 °C (200 °F). (e.g. mineral oil, ammonia) | |
REACT | 0 | Normally stable, even under fire exposure conditions, and is not reactive with water (e.g. helium,N2) | |
SPEC. HAZ. |
Advice for non-emergency personnel: Do not breathe vapors, aerosols. Avoid substance contact. Ensure adequate ventilation. Evacuate the danger area, observe emergency procedures, consult an expert.
For personal protection see section 8.
Do not let product enter drains.
Cover drains. Collect, bind, and pump off spills. Observe possible material restrictions (see sections 7 and 10). Take up carefully with liquid-absorbent material (e.g.
Chemizorb?). Dispose of properly. Clean up affected area.
For disposal see section 13.
Work under hood. Do not inhale substance/mixture. Avoid generation of vapours/aerosols.
Immediately change contaminated clothing. Apply preventive skin protection. Wash hands and face after working with substance.
For precautions see section 2.2.
Tightly closed. Keep in a well-ventilated place. Keep locked up or in an area accessible only to qualified or authorized persons.
Recommended storage temperature 2 - 8 °C
Air, light, and moisture sensitive.
Immediately change contaminated clothing. Apply preventive skin protection. Wash hands and face after working with substance.
Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Tightly fitting safety goggles
required
protective clothing
required when vapours/aerosols are generated.
Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system.
Do not let product enter drains.
No data available
The product is chemically stable under standard ambient conditions (room temperature) .
No data available
Air, light, and moisture sensitive. Strong heating.
Bases, Peroxides, Reacts violently with:, Strong acids
In the event of fire: see section 5
No data available
No data available
No data available
No data available
PBT/vPvB assessment not available as chemical safety assessment not required/not conducted
No data available
No data available
Toxicity to fish flow-through test LC50 - Lepomis macrochirus (Bluegill) - 15,400.0 mg/l - 96 h
(US-EPA)
Toxicity to daphnia and other aquatic invertebrates
semi-static test EC50 - Daphnia magna (Water flea) - 18,260 mg/l - 96 h
(OECD Test Guideline 202)
Toxicity to algae static test ErC50 - Pseudokirchneriella subcapitata (green algae) - ca. 22,000.0 mg/l - 96 h
(OECD Test Guideline 201)
Toxicity to bacteria static test IC50 - activated sludge - > 1,000 mg/l - 3 h (OECD Test Guideline 209)
Toxicity to fish static test LC50 - Leuciscus idus (Golden orfe) - 6,569 mg/l - 96 h
(DIN 38412 part 15)
Toxicity to daphnia and other aquatic invertebrates
static test EC50 - Daphnia magna (Water flea) - > 500 mg/l - 48 h
(Regulation (EC) No. 440/2008, Annex, C.2)
Toxicity to algae static test ErC50 - Desmodesmus subspicatus (green algae) - > 500 mg/l - 96 h
(DIN 38412)
Toxicity to bacteria static test EC50 - activated sludge - > 1,000 mg/l - 30 min (OECD Test Guideline 209)
Offer surplus and non-recyclable solutions to a licensed disposal company.
ADR/RID: - IMDG: - IATA-DGR: -
ADR/RID: - IMDG: - IATA-DGR: -
ADR/RID: - IMDG: - IATA-DGR: -
ADR/RID: no IMDG Marine pollutant: no IATA-DGR: no
Bases, Peroxides, Reacts violently with:, Strong acids
Not classified as dangerous in the meaning of transport regulations.
【1】CAMEO Chemicals, website: http://cameochemicals.noaa.gov/search/simple
【2】ChemIDplus, website: http://chem.sis.nlm.nih.gov/chemidplus/chemidlite.jsp
【3】ECHA - European Chemicals Agency, website: https://echa.europa.eu/
【4】eChemPortal - The Global Portal to Information on Chemical Substances by OECD, website: http://www.echemportal.org/echemportal/index?pageID=0&request_locale=en
【5】ERG - Emergency Response Guidebook by U.S. Department of Transportation, website: http://www.phmsa.dot.gov/hazmat/library/erg
【6】Germany GESTIS-database on hazard substance, website: http://www.dguv.de/ifa/gestis/gestis-stoffdatenbank/index-2.jsp
【7】HSDB - Hazardous Substances Data Bank, website: https://toxnet.nlm.nih.gov/newtoxnet/hsdb.htm
【8】IARC - International Agency for Research on Cancer, website: http://www.iarc.fr/
【9】IPCS - The International Chemical Safety Cards (ICSC), website: http://www.ilo.org/dyn/icsc/showcard.home
【10】Sigma-Aldrich, website: https://www.sigmaaldrich.com/
The information in this MSDS is only applicable to the specified product, unless otherwise specified, it is not applicable to the mixture of this product and other substances. This MSDS only provides information on the safety of the product for those who have received the appropriate professional training for the user of the product. Users of this MSDS must make independent judgments on the applicability of this SDS. The authors of this MSDS will not be held responsible for any harm caused by the use of this MSDS.